3M Equipment Control products reveal if the sterilizer is operating to set conditions of time, temperature, pressure, air removal, moisture conditioning and sterilant exposure. These products include:
3M™ Comply™ Disposable Bowie & Dick Test Pack
Bowie-Dick type test packs detect air leaks, inadequate air removal and steam penetration for vacuum-steam sterilizers. Compact, efficient and easy to use test packs compliant to BSEN 11140 part 4 and third party certified by BSI (kite marked).
Exposure
3M Exposure Control products help to distinguish between processed and unprocessed medical devices at a glance. They assure the sterilizer operator that each pack or item has been exposed to the sterilization process, without the need to open the pack.
3M™ Comply™ Dry-Heat Indicator Tape
This chemical indicator tape is designed for use as packaging tape and for the immediate identification of items exposed to dry heat processing.
3M™ Comply™ Ethylene Oxide Indicator Tape
A reliable indicator tape designed to facilitate the immediate identification of items exposed to an EO sterilization process, and for packaging purposes.
3M™ Comply™ Steam Indicator Tapes
The chemical indicators of choice for steam autoclaves for over 25 years.
Load
Load Control is the process by which a load is monitored and released based on the result of a biological or chemical indicator in a test pack or process challenge device. 3M has a full line of steam and EO biological indicators with results in as little as one hour, and chemical indicators of class 4, 5 and 6, providing instantaneous, unambiguous results.
3M Attest Biological Monitoring Indicators and Present Incubators
True biological indicators which are easy to use and give a clear colour change results within 24 to 48 hours of processing.
3M Attest Rapid Readout Biological Monitoring System
The 3M Attest Rapid Readout Biological Monitoring System consists of true biological indicators, that provide clear, easy to interpret biological results in just 1 - 4 hours.
Pack
Pack control involves the use of chemical indicators for internal monitoring of packs, trays, containers and peel pouches. The appropriate product from 3M’s wide range of chemical indicators is placed inside each pack and immediately identifies whether the conditions for sterilization have been met.
3M™ Comply™ Colour Change Chemical Indicators
Reliable, multi-variable indicator strips that offer an accurate and consistent low-cost method of monitoring the sterilization process.
3M™ Comply™ Sequential Response Chemical Indicators
Sequential response multi-variable indicator strips react sequentially to the parameters of sterilization, such as time, steam and temperature. They also provide some indication of sterilant quality.
3M™ Comply™ (SteriGage™) Steam and EO Chemical Indicators
Designed to monitor exposure to steam or EO conditions in a pack. Provides a visual accept/reject readout to determine that the sterilant has penetrated to the point of placement in the pack and confirm that sufficient exposure conditions occurred.
3M™ Steri-Dual™ ECO Packaging
Packaging for steam and ethylene oxide sterilization that provides a breathable barrier which allows sterilant to permeate during the sterilization process while prohibiting microbial penetration during handling and storage after sterilization. Available in flat sheets (blue and green) and reels (gusseted and flat).
Record
The final touch to a complete sterilization process monitoring system is Record Keeping. It documents the materials that have been processed and their monitoring control evidence. The system enables you to keep track of the process using record keeping envelopes, forms and labels. If you've ever run into a recall situation that forced you to investigate the source of the problem, you know how valuable this can be.
3M Attest Log Book
Our Attest Log Book contains 50 record charts for for logging steam and EO sterilizer results.
Low Temperature Sterilization Solutions
Proven effective for broad use, low temperature sterilization of heat and moisture sensitive medical instruments and devices
3M™ Steri-Vac™ 5XL and 8XL dual-cycle 100% ethylene oxide (EO) gas sterilizer/aerator systems are designed to provide today’s highest level of sterilization assurance – using time-tested EO technology that has proven to offer a safe, effective and economical solution for low temperature sterilization applications. Ethylene oxide is a highly-penetrating sterilant that offers superior efficacy for complex instrumentation, such as flexible endoscopes, and is compatible with most device materials. In fact, there are minimal design or lumen restrictions with EO technology, helping to simplify your sterilization procedures.
Standing the test of time
3M Steri-Vac systems have provided safe, effective and economical sterilization for decades. In fact, over half of all heat or moisture sensitive devices (including sterile single use devices made by manufacturers) are sterilized with ethylene oxide. There are a number of other low- and high-temperature sterilizing technologies that do have their place in a healthcare facility’s overall equipment strategy; however, for best practice on today’s most critical low temperature sterilization challenges, you can rely on 3M Steri-Vac EO Systems.
3M™ EO Abator Model 50 System
The abator takes ethylene oxide (EO) gas exhausted from 3M™ Steri-Vac™ Sterilizers and Aerators, converting it to CO2 and water vapor. At normal operating temperatures and concentrations, removal efficiency is 99.9+%.
3M™ Ethylene Oxide Monitor
A lightweight badge with ethylene-oxide sensitive material that clips to lapel or pocket near breathing zone for monitoring of personnel during a work shift.
3M™ Steri-Gas™ EO Cartridges
A single-dose cartridge containing 100% ethylene oxide (EO). Each cartridge holds between 3.5 to 6 ounces (100 to 170 grams) of EO depending on the model of 3M™ Steri-Vac™ Sterilizer used.
3M™ Steri-Vac Sterilizer/Aerator Model 5XL
A dual-cycle, 100% ethylene oxide (EO) gas sterilizer/aerator with a 4.8 cubic foot chamber. It can be installed in a wall or placed on a freestanding rack. Includes upper and lower baskets, and installation kit. A local exhaust hood is available.
3M™ Steri-Vac Sterilizer/Aerator Model 8XL
A dual-cycle, 100% ethylene oxide (EO) gas sterilizer/aerator with a large 7.9 cubic foot chamber. It can be installed in a wall or placed free-standing in the room. Includes upper half baskets and lower basket, and an installation kit.
3M™ Steri-Vac™ Aeration Cabinets
An aeration cabinet that provides constant air flow and temperature for the separate aeration of EO sterilized items. Designed for use with 3M™ Steri-Vac™ Sterilizers, it offers two aeration temperatures: 37°C/99°F or 55°C/130°F.
3M™ Steri-Vac™ Miscellaneous Accessories and Supplies
3M offers all the accessories and supplies you will need to set up or operate your 100% EO sterilizer.
3M™ Transfer Cart
A transfer cart designed to assist operators who move, lift or lower materials and supplies around the Sterile Processing Department. Includes controls that raise and lower the table to appropriate height.
Accessory Baskets for 3M™ Steri-Vac™ Sterilization Equipment
Variety of chrome and stainless steel baskets and dividers for use in 3M Steri-Vac Sterilizer Systems.
Printer Paper for 3M™ Steri-Vac™ Sterilization Equipment
Paper printer rolls for 3M™ Steri-Vac™ Sterilizers.
Stacking Racks for 3M™ Steri-Vac™ Sterilization Equipment
Free-standing and in-wall stacking racks for two 3M™ Steri-Vac™ sterilizers/aerators.